Online 15W UV Laser Marking Machine DANA F2015
description1
description2
Advantages
1. UV laser marking machine uses a narrow pulse width of laser, and the processing material action time is short, the thermal effect is small, the material is not deformed and not burnt, the effect of marking is more beautiful.
2. UV Laser has thinner laser printing line than CO2 laser and fiber laser ,it enables the UV laser marking deliver ultra-fine printing on a small package
3. The system incorporates an automatic coding function, capable of generating variable data such as serial numbers, batch numbers, and dates tailored to specific user requirements on user requirements. It is compatible with popular software applications including AUTOCAD, CORELDRAW, PHOTOSHOP, CAXA, and others. It supports a wide range of file formats including PLT, PCX, DXF, BMP, and more.
4. It's for permanent marking with no consumables. Five power levels can be selected according to your needs.
Samples
Technical Parameters
DANA F2015 UV Laser Marking Machine Specification | |
Laser-type |
UV Laser Wavelength: 355nm, 25000hrs continuous working time |
Power Output Class |
15W |
Focal Length |
188mm(Standard) |
Maximum line marking speed |
25m-30m/min (according to the marking content and requirements) |
Marking parameters | |
Marking Field |
110mm × 110mm; Max: 550mm × 550mm |
Marking lines |
Set any line numbers within the valid marking range |
Minimum Line Width |
0.01mm |
Production Line Speed |
Depending on the marking content |
Character Height |
0.2-70mm |
Typeface |
Single line, dot matrix, True Type |
Marking Content |
Text, Graphics, Bar code, Two-dimensional code, Dynamic serial number, real-time clock, TXT file, RS232 communication data, etc.. |
Marking Angle |
Any Angle, adjustable in 4 dimensions |
Operation Interface | |
Monitor |
Industrial Touchscreen |
Operating Language |
Chinese, English and other Languages |
Operating System |
Linux |
Input Method |
Handwriting |
Working Environment Requirements
Environment Requirements | |
Protection Degree |
≥IP54 |
Cooling |
Water-Cooling |
Operating Temperature |
-5-45 degrees Celsius |
Operating Humidity |
80% RH,Non-Condensing |
Power Supply |
220V,1KVA |